Electrical calculations for cables, diversity, voltage drop, etc. (part 4 of 4)
Since this is a theoretical situation, the exact pathways for cables, the location of the consumer unit and correction factors are unknown. And so, again, I took liberties in choosing data for calculations. The assumptions made in the following calculations are as follows:
Ca = 1 (ambient temperature for all circuits is 30 degrees)
Cg = 1 (there is no grouping in installation)
Ci = 1 (installed as per Table F6 O.S.G.)
Cf = 1 (it is a new installation and BS 3036 will not be used)
Reference Method used is C
The hob, oven and hood are installed on the same circuit with an additional socket.
Socket-outlet ring/radial circuits will be constructed as per Appendix H (O.S.G.)
Total length of the circuits are taken as follows:
Lights - 20 m
Cooker - 10 m
Heating - 15 m
Shower - 20 m
Following these assumptions the results of the calculations are: